{"product_id":"siemens-5sy4132-7","title":"5SY4132-7","description":"\u003ch2\u003eOverview of Siemens 5SY4132-7\u003c\/h2\u003e\n\u003cp\u003eBuy genuine Siemens 5SY4132-7 online directly from LeadTime.ca for your automation system. The Siemens 5SY4132-7 is a premium, single-pole supplementary miniature circuit breaker rated for 32 A, featuring a thermal-magnetic trip mechanism and C-curve tripping characteristic—ideal for protecting sensitive circuits in industrial, commercial, and machine automation applications. This reliable accessory is designed for fast, selective interruption, reducing downtime by isolating faults without affecting adjacent circuits. With a robust DIN rail mount, industrial IP20 enclosure, and compliance with international standards, this breaker is a trusted choice for demanding automation environments where protection, selectivity, and ease of installation are required.\u003c\/p\u003e\n\u003ch2\u003eKey Features of Siemens 5SY4132-7\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eSingle-pole, 32 A miniature supplementary circuit breaker\u003c\/li\u003e\n  \u003cli\u003eC-curve tripping characteristic for medium inrush current applications\u003c\/li\u003e\n  \u003cli\u003eThermal-magnetic trip mechanism for reliable protection\u003c\/li\u003e\n  \u003cli\u003eCompact DIN rail mounting, fits standard 35 mm rails\u003c\/li\u003e\n  \u003cli\u003eIndustrial enclosure rated IP20 for panel safety\u003c\/li\u003e\n  \u003cli\u003eShort-circuit breaking capacity of 10 kA at 230\/400 VAC\u003c\/li\u003e\n  \u003cli\u003eOperating temperature range: -25°C to +75°C for extreme conditions\u003c\/li\u003e\n  \u003cli\u003eMechanical service life: 10,000 switching cycles\u003c\/li\u003e\n  \u003cli\u003eWide wire compatibility: 1 to 25 mm² (AWG 14 to 4)\u003c\/li\u003e\n  \u003cli\u003eTerminals with finger protection for safe installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specs of Siemens 5SY4132-7\u003c\/h2\u003e\n\u003cp\u003eReview Siemens 5SY4132-7 specifications for detailed parameters to ensure system compatibility.\u003c\/p\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003cth\u003eParameter\u003c\/th\u003e\n    \u003cth\u003eValue\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003ePoles\u003c\/td\u003e\n    \u003ctd\u003e1\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRated Current\u003c\/td\u003e\n    \u003ctd\u003e32 A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRated Voltage\u003c\/td\u003e\n    \u003ctd\u003e230\/400 VAC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eShort-Circuit Capacity\u003c\/td\u003e\n    \u003ctd\u003e10 kA\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eTrip Type\u003c\/td\u003e\n    \u003ctd\u003eC (Thermal-magnetic)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eWire Size\u003c\/td\u003e\n    \u003ctd\u003e1–25 mm² (14–4 AWG)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eMounting\u003c\/td\u003e\n    \u003ctd\u003eDIN Rail (35 mm)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n    \u003ctd\u003e90 x 18 x 70 mm (approx.)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eEnclosure\u003c\/td\u003e\n    \u003ctd\u003eIP20\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n    \u003ctd\u003e-25°C to +75°C\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eApplications \/ Use Case\u003c\/h2\u003e\n\u003cp\u003eThis Siemens 5SY4132-7 is commonly used in industrial automation and factory control panels worldwide. It’s ideal for protecting sensitive downstream devices in machine automation, production lines, and packaging systems—where fast tripping and selectivity prevent cascading failures. The device also serves as a local disconnecting means within control panels, ensuring quick fault isolation without shutting down entire systems. Whether you are upgrading an existing plant or specifying new automation equipment, this supplementary protector is engineered for reliability in the most demanding manufacturing environments.\u003c\/p\u003e\n\u003ch2\u003ePrice \u0026amp; Availability\u003c\/h2\u003e\n\u003cp\u003eView Siemens 5SY4132-7 price and availability through LeadTime.ca for fast worldwide dispatch.\u003c\/p\u003e\n\u003ch2\u003eWhy Order from LeadTime.ca\u003c\/h2\u003e\n\u003cp\u003eEvery product on LeadTime.ca is genuine, sourced from verified suppliers, and available for worldwide shipping. Order now for worldwide delivery and benefit from a streamlined checkout experience, trusted after-sales support, and quick global dispatch of your Siemens automation parts.\u003c\/p\u003e\n\u003ch2\u003eRelated Resources\u003c\/h2\u003e\n\u003cp\u003e\n  \u003ca href=\"https:\/\/leadtime.ca\/\"\u003eLeadTime.ca – Industrial Automation Components \u0026amp; Repair Services\u003c\/a\u003e\u003cbr\u003e\n  \u003ca href=\"https:\/\/leadtime.ca\/collections\/siemens\"\u003eBrowse Siemens PLCs, Drives \u0026amp; Automation Parts\u003c\/a\u003e\u003cbr\u003e\n  \u003ca href=\"https:\/\/leadtime.ca\/blogs\/learning-center\/siemens-plc-programming-basics\"\u003eSiemens PLC programming guide\u003c\/a\u003e\u003cbr\u003e\n  \u003ca href=\"https:\/\/leadtime.ca\/blogs\/learning-center\/siemens-tia-portal-trace-errors\"\u003eHow to trace Siemens TIA Portal errors\u003c\/a\u003e\u003cbr\u003e\n  \u003ca href=\"https:\/\/leadtime.ca\/blogs\/learning-center\/siemens-drive-parameter-setup\"\u003eSiemens drive parameter setup reference\u003c\/a\u003e\n\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":47796294418731,"sku":null,"price":22.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/4671\/7995\/files\/Leadtime_f387dd1d-4d07-4050-85f1-034cfa2257f4.png?v=1723552506","url":"https:\/\/leadtime.ca\/products\/siemens-5sy4132-7","provider":"LEADTIME","version":"1.0","type":"link"}