{"product_id":"siemens-3rv1011-1ka10","title":"3RV1011-1KA10","description":"\u003ch2\u003eBuy genuine Siemens 3RV1011-1KA10 online for your automation system\u003c\/h2\u003e\n\u003cp\u003eThe Siemens 3RV1011-1KA10 is a reliable manual motor protector from the Siemens Sirius series, designed to safeguard motors with a thermal-magnetic trip mechanism adjustable between 9 to 12.5 amps. This motor starter protector features an ON\/OFF rocker switch, class 10 overload trip characteristics, and is DIN rail mountable for easy installation. Its robust construction includes bimetallic heating elements for overload protection and a unique fourth bimetallic strip to prevent nuisance tripping caused by panel temperature rise. Additionally, it is phase loss sensitive, which quickly trips in under 10 seconds to prevent motor damage, making it ideal for industrial motor protection applications. Its compact design and reliable performance suit a wide range of automation and motor control systems.\u003c\/p\u003e\n\u003ch2\u003eKey Features of Siemens 3RV1011-1KA10\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eAdjustable thermal overload protection from 9 to 12.5 amps\u003c\/li\u003e\n  \u003cli\u003eClass 10 trip curve for quick, reliable overload response\u003c\/li\u003e\n  \u003cli\u003ePhase loss sensitive to prevent motor damage\u003c\/li\u003e\n  \u003cli\u003eManual ON\/OFF rocker mechanism with lockout feature\u003c\/li\u003e\n  \u003cli\u003eMagnetic short-circuit trip for additional motor protection\u003c\/li\u003e\n  \u003cli\u003eScrew terminal connections for secure wiring\u003c\/li\u003e\n  \u003cli\u003eCompact footprint, mountable on a standard 35mm DIN rail\u003c\/li\u003e\n  \u003cli\u003eOptional auxiliary contacts available for motor disconnection or signaling\u003c\/li\u003e\n  \u003cli\u003eAmbient temperature compensation to avoid false trips\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specs of 3RV1011-1KA10\u003c\/h2\u003e\n\u003cp\u003eExplore Siemens 3RV1011-1KA10 datasheet for detailed parameters to ensure system compatibility.\u003c\/p\u003e\n\u003ctable\u003e\n  \u003ctr\u003e\n    \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003cth\u003eDetails\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eRated Current\u003c\/td\u003e\n    \u003ctd\u003e9 to 12.5 A adjustable\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eTrip Class\u003c\/td\u003e\n    \u003ctd\u003eClass 10\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eDimensions (HxWxD)\u003c\/td\u003e\n    \u003ctd\u003e90 mm x 45 mm x 75-81 mm\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eEnclosure Type\u003c\/td\u003e\n    \u003ctd\u003eIP20\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eFrame Size\u003c\/td\u003e\n    \u003ctd\u003e3RV1\/S00\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eFrequency Rating\u003c\/td\u003e\n    \u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eConnection\u003c\/td\u003e\n    \u003ctd\u003eScrew terminals\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003eMounting\u003c\/td\u003e\n    \u003ctd\u003eDIN Rail\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eApplications \/ Use Case\u003c\/h2\u003e\n\u003cp\u003eThis Siemens 3RV1011-1KA10 is commonly used in industrial automation environments to provide dependable motor protection. It is widely implemented within production line systems, pump panels, HVAC motor controls, and factory control panels. Its reliable trip characteristics and phase loss sensitivity ensure that critical motors are effectively shielded from overload, short circuits, and phase loss conditions. This motor protector is an excellent choice for process control and machine automation setups requiring consistent motor safety and system uptime.\u003c\/p\u003e\n\u003ch2\u003ePrice \u0026amp; Availability\u003c\/h2\u003e\n\u003cp\u003eCheck Siemens 3RV1011-1KA10 pricing online through LeadTime.ca for fast worldwide dispatch.\u003c\/p\u003e\n\u003ch2\u003eWhy Order from LeadTime.ca\u003c\/h2\u003e\n\u003cp\u003eAll product on LeadTime.ca is genuine, original OEM, supplied by trusted distributors, and supported with manufacturer warranty, ready for international delivery. Order now for worldwide delivery.\u003c\/p\u003e\n\u003ch2\u003eRelated Resources\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/leadtime.ca\/\"\u003eLeadTime.ca – Industrial Automation Components \u0026amp; Repair Services\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/leadtime.ca\/collections\/siemens\"\u003eBrowse Siemens PLCs, Drives \u0026amp; Automation Parts\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/leadtime.ca\/blogs\/learning-center\/siemens-plc-programming-basics\"\u003eSiemens PLC Programming Basics\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/leadtime.ca\/blogs\/learning-center\/siemens-tia-portal-io-errors\"\u003eTroubleshooting Siemens TIA Portal I\/O Errors\u003c\/a\u003e\u003c\/li\u003e\n  \u003cli\u003e\u003ca href=\"https:\/\/leadtime.ca\/blogs\/learning-center\/siemens-drive-parameter-setup\"\u003eSiemens Drive Parameter Setup Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":47796242252075,"sku":null,"price":76.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0837\/4671\/7995\/files\/Leadtime_6ac2f0d5-1b53-4618-bc3a-4297db76d3bc.png?v=1723553188","url":"https:\/\/leadtime.ca\/products\/siemens-3rv1011-1ka10","provider":"LEADTIME","version":"1.0","type":"link"}